| Mode | 
				GU-G613N                                         GU-G613P | 
		
| 
				Type | 
			
				thrubeam | 
		
| 
				Action mode | 
			
				ON in shading light ON in entering light | 
		
| 
				Detecting objects | 
			
				Liquid in the catheter (such as high viscosity or suspended solids, may not be detected) | 
		
| 
				Action indicator | 
			
				Red status indicator; green output indicator | 
		
| 
				Connection method | 
			
				Wire lead (standard wire length 2m) | 
		
| 
				Voltage | 
			
				DC12~24V±10% ripple (P-P) 5% or less | 
		
| 
				Current consumption | 
			
				The average value is below 30 mA and the maximum value is below 80 mA | 
		
| 
				Suitable catheter | 
			
				Transparent catheter with outer diameter Φ6~13mm (thickness 1mm) | 
		
| 
				Light source | 
			
				GaAs infrared light-emitting diode (940nm) | 
		
| 
				Ambient illumination | 
			
				Incandescent lamp - sunlight: each below 3000Lux | 
		
| 
				Ambient temperature | 
			
				When working: -10~+55°C When saving: -25~+65°C (No icing,No condensation) | 
		
| 
				Ambient humidity | 
			
				Working: 5~85%RH Saving: 5~95% (No icing,No condensation) | 
		
| 
				Environment vibration | 
			
				10~500Hz single amplitude 1.0mm | 
		
| 
				Environment compact | 
			
				500m/s2 X, Y, Z 3 times in each direction | 
		
| 
				Protective structure | 
			
				IEC specification Ip50 | 
		
| 
				Control output | 
			
				Load power supply voltage DC12~24V, load current below 100mA Shutdown power supply below 0.5mA, residual voltage below 0.8V Residual voltage is below 0.4V (when load current is 40mA)  | 
		
| 
				Output Type | 
			
				NPN open collector output type    PNP open collector output type | 
		
| 
				Housing material | 
			
				Polycarbonate |